כל הפנס מאותת ללא הוינקר
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(12) -Leuchte23SL HLC10-Lichtfunktion E 23# in the drop-down list
Select "Blinken links Hellphase"
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(14) -Leuchte23SL HLC10-Dimmwert EF 23# in the drop-down list
Set the value 100
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(15) -Leuchte23SL HLC10-Dimming Direction EF 23# in the drop-down list
Select maximizes
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(16) -Leuchte23SL HLC10-Lichtfunktion G 23# in the drop-down list
Select #Blinken links Dunkelphase#
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(18) -Leuchte23SL HLC10-Dimmwert GH 23# in the drop-down list
Set the value 0
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(19) -Leuchte23SL HLC10-Dimming Direction GH 23# in the drop-down list
Select minimize
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(12) -Leuchte24SL HRA65-Lichtfunktion E 24# in the drop-down list
Select "Blinken rechts Hellphase"
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(14) -Leuchte24SL HRA65-Dimmwert EF 24# in the drop-down list
Set the value 100
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(15) -Leuchte24SL HRA65-Dimming Direction EF 24# in the drop-down list
Select maximizes
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(16) -Leuchte24SL HRA65-Lichtfunktion G 24# in the drop-down list
Select "Blinken rechts Dunkelphase"
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(18) -Leuchte24SL HRA65-Dimmwert GH 24# in the drop-down list
Set the value 0
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(19) -Leuchte24SL HRA65-Dimming Direction GH 24# in the drop-down list
Select minimize
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(12) -Leuchte26NSL LA72-Lichtfunktion E 26# in the drop-down list
Select "Blinken links Hellphase"
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(14) -Leuchte26NSL LA72-Dimmwert EF 26# in the drop-down list
Set the value 100
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(15) -Leuchte26NSL LA72-Dimming Direction EF 26# in the drop-down list
Select maximizes
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(16) -Leuchte26NSL LA72-Lichtfunktion G 26# in the drop-down list
Select #Blinken links Dunkelphase#
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(18) -Leuchte26NSL LA72-Dimmwert GH 26# in the drop-down list
Set the value 0
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(19) -Leuchte26NSL LA72-Dimming Direction GH 26# in the drop-down list
Select minimize
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(12) -Leuchte27NSL RC6-Lichtfunktion E 27# in the drop-down list
Select "Blinken rechts Hellphase"
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(14) -Leuchte27NSL RC6-Dimmwert EF 27# in the drop-down list
Set the value 100
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(15) -Leuchte27NSL RC6-Dimming Direction EF 27# in the drop-down list
Select maximizes
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(16) -Leuchte27NSL RC6-Lichtfunktion G 27# in the drop-down list
Select "Blinken rechts Dunkelphase"
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(18) -Leuchte27NSL RC6-Dimmwert GH 27# in the drop-down list
Set the value 0
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(19) -Leuchte27NSL RC6-Dimming Direction GH 27# in the drop-down list
Select minimize
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(4) -Leuchte18BLK HLA60-Dimming Direction A 18# in the drop-down list
Select not active
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(8) -Leuchte18BLK HLA60-Dimming Direction C 18# in the drop-down list
Select not active
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - #(4) -Leuchte19BLK HRC31-Dimming Direction A 19# in the drop-down list
Select not active
[09 - Power Plant/Central Electrics] - [Security Code: 31347] - [Adaptation - 10] - "(8) -Leuchte19BLK HRC31-Dimming Direction C 19" in the drop-down list
Select not active
בנוסף אפשר לבדוק איתותים אחרים :